Skip to main content

KL731A

KILSEN KA700 Series addressable optical smoke detector
  • Remote signalling capabilities
  • Easy soft addressing (1-125)
  • SMD technology
  • Reliable communication protocol
  • Full diagnostic self testing
View all

At a glance

Product overview

The KL700A series detectors use an enhanced protocol that ensures the overall integrity and error free operation of the system. All detectors are compatible with a standard base and support the connection of a remote indicator.

KL710A heat detector

An alarm is raised when the temperature exceeds a fixed temperature or the rate-of-rise of temperature is exceeded. It is used where a fire could cause an abrupt elevation of the temperature, or where smoke of controlled combustion, aerosols, etc. do not allow the use of any other type of detector.

KL731A/B optical smoke detectors

The Tyndall optical effect of smoke in a chamber is used to detect a fire. It is used in areas where possible combustible materials, like plastics, polystyrene, PVC, etc., generate visible smoke.

For installations with false ceilings or black ceilings where detectors should not be visible, this device is also available in black with a black detector base.

The addressable optical detector is available in either white or black colours.

KL735A dual detector

Dual technology (one photoelectric and two heat sensors) is used for accurate detection of various types of fires. The heat detection is based on a fixed and rate-of-rise response whilst the photoelectric sensor uses the Tyndall optical effect.

User friendly

Detectors are identified by soft addressing. The address is stored in flash memory and eliminates the risk of addresses being changed without authorization. Other addressable accessories include conventional zone monitors, various in- and output units, sounder controllers, manual call points and isolators.

Details

  • Remote signalling capabilities
  • Easy soft addressing (1-125)
  • SMD technology
  • Reliable communication protocol
  • Full diagnostic self testing
  • Full range: Optical and Heat and Dual detectors (optical/heat)
  • Full range of supporting I/O units and accessories
  • EN54 approved and CPR certified

Technical specifications

General
Status indication
Red (dual LED, alarm)
Compatibility
Kilsen addressable fire systems
Alarm levels
Configurable
Connectivity
2-wire loop
Addressing method
Electronic
Electrical
Power supply type
Loop powered
Operating voltage
22 to 38 VDC
Current consumption
350 µA (quiescent @ 38 VDC)
<11 mA (in alarm)
Detection
Detection principle
Optical, light scatter
Monitoring
Alarm threshold
Contamination level
Continuously self-checking
Coverage area
60 to 80 m²
Output
Output quantity
1
Output type and rating
Remote indicator
Physical
Physical dimensions
45 x 99 mm (H x Ø)
Net weight
107 g
Colour
White (RAL 9010-P)
Mounting type
Base mount
Wall mount
Environmental
Vandal proof
No
Operating temperature
-10 to +60°C
Storage temperature
-10 to +70°C
Relative humidity
0 to 95% noncondensing
Environment
Indoor
IP rating
IP42
Regulatory
Compliancy
CE
REACH
RoHS 3
WEEE
Certification
CPR
Standards
EN54-7